HomeStore

Juniper ACX6360-OR-DC Router

Juniper ACX6360-OR-DC Router

[shortdesc]
  • ACX6400, Optical Router configuration, 20 x 100GbE QSFP28/QSFP+ client ports, 8 x 100/200G CFP2-DCO pluggable DWDM optics, redundant fans and redundant DC power supplies, front to back airflow
[/shortdesc]

[properties]

Properties Juniper ACX6360-OR-DC
Description ACX6360 Optical Router configuration, 20x100GbE QSFP28/QSFP+ client ports, 8x100/200G CFP2-DCO pluggable DWDM optics, redundant fans and redundant DC power supplies, front-to-back airflow
Product Family ACX6000 Series
Product Type Router
Built-In Interface Options
10GbE (SFP+) 80**
40GbE (QSFP) 20
100GbE (QSFP28) 20
100/200 Gbps (CFP2-DCO) 8
**Via QSFP+ 4x10GbE breakout
Dimension (WxHxD) 17.36 x 1.72 x 24.40 in (44.09 x 4.37 x 61.98 cm)
Weight (lb/kg) fully configured 30 lb (13.6 kg)
Power -40 to -72 VDC power
Maximum power draw 756 W (with optical SFP transceivers)
Rack unit 1 U

[/properties][specifications]

Specifications ACX6360-OR-DC
System Throughput 3.6/7.2 Tbps
Operating temperature 32° to 104° F (0° to 40° C)
Humidity 5%-90% RH noncondensing
Platform Features Link Aggregation Control Protocol (LACP)
Link Layer Discovery Protocol (LLDP)
IPv4
IPv6
RPF
Equal-cost multipath (ECMP)
Enhanced load balancing based on L2-L4 header info
OSPF
IS-IS
BGP
Indirect/composite next hop
RSVP
LDP
Path Computation Element Protocol (PCEP)
RSVP-TE
BGP-LU
LDP-RSVP
RSVP fast reroute (FRR)
Segment routing
IEEE 802.1AE/802.1X industry-compliant 256AES MACsec
CLI
NETCONF
SNMP v2/v3
SLAX/Python on-box scripting tools
ZTD
YANG
Safety Approvals CAN/CSA-C22.2 No. 60950-1
UL 60950-1
EN 60950-1
IEC 60950-1CB Scheme
EN 60825-1
EMC AS/NZS CISPR22
Class A
EN55022 Class A
VCCI Class A
FCC Part 15 Class A
IECS-003 Issue 4
BSMI CNS 13438 and NCC C6357 Taiwan Radiated Emissions
KN 22, Class
EN-61000-4-6 Low Frequency Common Immunity
EN-61000-4-11 Voltage Dips and Sags
CISPR 24/EN55024 Information Technology Equipment Immunity
Characteristics
ETSI (European Telecommunications Standardization Institute) EN 300 386 V1.6.1 Telecommunication Network Equipment, Electromagnetic Compatibility Requirements
ETSI EN 300 019-2-1 (2000)Storage, Class T1.2
ETSI EN 300 019-2-2 (1999)Transportation, Class T2.3
ETSI EN 300 019-2-3 (2003)Stationary Use at Weather
Protected Locations, Class T3.2
ETSI 300753 (1997)Acoustic Noise Emitted by Telecommunications Equipment
Other EMC Requirements Deutsche Telekom 1TR9 (2008) EMC Specification
British Telecom EMC Immunity Requirements (2007)
NEBS SR-3580 NEBS Criteria Levels (Level 3 Compliance)
GR-63-CORE: NEBS, Physical Protection
Telecommunications Equipment (Issue 6 compliant)
Telecomm Compliance Device management: NETCONF, CLI, SNMP v1/v2/v3
End-to-end provisioning of E-Line, emulated LAN (ELAN), Layer 3 VPN (L3VPN), OAM, class of service (CoS)
Device and service-level fault management
Device and service-level performance management

[/specifications][accesories] [/accesories]

Juniper ACX6360-OR-DC Router

Juniper ACX6000 line of Universal Metro Routers directly addresses evolving metro network architectures that extend operational intelligence from the service provider edge to the access network. The ACX6000 line bridges the complexity between packet optical transport and the IP/MPLS networking layer by collapsing both domains into a seamless, multilayer solution. From there, it delivers a single-pane-of-glass view into network operations.

$64,562.40

Original: $184,464.00

-65%
Juniper ACX6360-OR-DC Router

$184,464.00

$64,562.40
Product image 1

Description

[shortdesc]
  • ACX6400, Optical Router configuration, 20 x 100GbE QSFP28/QSFP+ client ports, 8 x 100/200G CFP2-DCO pluggable DWDM optics, redundant fans and redundant DC power supplies, front to back airflow
[/shortdesc]

[properties]

Properties Juniper ACX6360-OR-DC
Description ACX6360 Optical Router configuration, 20x100GbE QSFP28/QSFP+ client ports, 8x100/200G CFP2-DCO pluggable DWDM optics, redundant fans and redundant DC power supplies, front-to-back airflow
Product Family ACX6000 Series
Product Type Router
Built-In Interface Options
10GbE (SFP+) 80**
40GbE (QSFP) 20
100GbE (QSFP28) 20
100/200 Gbps (CFP2-DCO) 8
**Via QSFP+ 4x10GbE breakout
Dimension (WxHxD) 17.36 x 1.72 x 24.40 in (44.09 x 4.37 x 61.98 cm)
Weight (lb/kg) fully configured 30 lb (13.6 kg)
Power -40 to -72 VDC power
Maximum power draw 756 W (with optical SFP transceivers)
Rack unit 1 U

[/properties][specifications]

Specifications ACX6360-OR-DC
System Throughput 3.6/7.2 Tbps
Operating temperature 32° to 104° F (0° to 40° C)
Humidity 5%-90% RH noncondensing
Platform Features Link Aggregation Control Protocol (LACP)
Link Layer Discovery Protocol (LLDP)
IPv4
IPv6
RPF
Equal-cost multipath (ECMP)
Enhanced load balancing based on L2-L4 header info
OSPF
IS-IS
BGP
Indirect/composite next hop
RSVP
LDP
Path Computation Element Protocol (PCEP)
RSVP-TE
BGP-LU
LDP-RSVP
RSVP fast reroute (FRR)
Segment routing
IEEE 802.1AE/802.1X industry-compliant 256AES MACsec
CLI
NETCONF
SNMP v2/v3
SLAX/Python on-box scripting tools
ZTD
YANG
Safety Approvals CAN/CSA-C22.2 No. 60950-1
UL 60950-1
EN 60950-1
IEC 60950-1CB Scheme
EN 60825-1
EMC AS/NZS CISPR22
Class A
EN55022 Class A
VCCI Class A
FCC Part 15 Class A
IECS-003 Issue 4
BSMI CNS 13438 and NCC C6357 Taiwan Radiated Emissions
KN 22, Class
EN-61000-4-6 Low Frequency Common Immunity
EN-61000-4-11 Voltage Dips and Sags
CISPR 24/EN55024 Information Technology Equipment Immunity
Characteristics
ETSI (European Telecommunications Standardization Institute) EN 300 386 V1.6.1 Telecommunication Network Equipment, Electromagnetic Compatibility Requirements
ETSI EN 300 019-2-1 (2000)Storage, Class T1.2
ETSI EN 300 019-2-2 (1999)Transportation, Class T2.3
ETSI EN 300 019-2-3 (2003)Stationary Use at Weather
Protected Locations, Class T3.2
ETSI 300753 (1997)Acoustic Noise Emitted by Telecommunications Equipment
Other EMC Requirements Deutsche Telekom 1TR9 (2008) EMC Specification
British Telecom EMC Immunity Requirements (2007)
NEBS SR-3580 NEBS Criteria Levels (Level 3 Compliance)
GR-63-CORE: NEBS, Physical Protection
Telecommunications Equipment (Issue 6 compliant)
Telecomm Compliance Device management: NETCONF, CLI, SNMP v1/v2/v3
End-to-end provisioning of E-Line, emulated LAN (ELAN), Layer 3 VPN (L3VPN), OAM, class of service (CoS)
Device and service-level fault management
Device and service-level performance management

[/specifications][accesories] [/accesories]

Juniper ACX6360-OR-DC Router

Juniper ACX6000 line of Universal Metro Routers directly addresses evolving metro network architectures that extend operational intelligence from the service provider edge to the access network. The ACX6000 line bridges the complexity between packet optical transport and the IP/MPLS networking layer by collapsing both domains into a seamless, multilayer solution. From there, it delivers a single-pane-of-glass view into network operations.